Azteca A-446 Steam Sterilizer Celitron

Product Code:s A 446

checked-shape
In Stock
2 160 836 грн
  • The consultation on assortment of equipment
  • The manufacturer's official warranty is 12 months
  • Free staff training
  • Certified customer service
  • Service support during the warranty and post-warranty period


Azteca A-446 Steam Sterilizer Celitron

Product Description
Azteca A-446 is a fully automatic high-speed pre & post vacuum steam sterilizer.
This model is an electrically heated sterilizer, which operates with saturated steam as a sterilizing agent, and has a temperature between 121°C (250°F) and 134ºC (273°F) and pressure up to 2.5 bars (36.3 psi).
The autoclave is classified as Class IIb according to MDD 93/42/EEC. The autoclave is designed as a Large Steam Sterilizer in accordance with EN285 and as Class I in accordance with EN60601-1, continuously operated, ordinary equipment without applied parts and without signal input-output parts. The device is not intended for use in the presence of flammable mixtures.

The sterilizer includes the following features:

  • Large capacity sterilization chamber
  • Vacuum pump for evacuation of the chamber
  • Fully automatic door locking system – activated with one button on the display or with foot pedal
  • Water reservoir for process and used water retention
  • Water pump for water circulation
  • Condenser and collector for condensation and collection of water
  • Temperature sensors and a pressure transducer to monitor both vacuum and pressurized states
  • Control valves operating at programmed intervals

Application
The unit is designed to cover a large field of applications for hospital CSSDs, pharmaceutical and biotechnological applications.

Dimensions
Inner chamber dimensions W x H x D: 406 x 406 x 670 mm

Chamber volume: 110 Litres

External dimensions W x H x D: 660 x 1900 x 910 mm  

Max. electric power with steam generator 14 kW, 3 phase, 380-400V – 3 x 25A, 50/60 Hz

 Technical data

Inner chamber dimensions W x H x D *

406 x 406 x 670 mm

Chamber volume *

110 l

External dimensions W x H x D

660 x 1900 x 910 mm

Approximate weight

350 kg

Power supply**

3 ph. 380-400 V, 50/60 Hz

Available sterilization cycles

Flash 134 °C / Unwrapped 134 °C / Wrapped 134 °C / Prion 134 °C / Porous 121 °C


Azteca A-446 Steam Sterilizer Celitron

Product Description
Azteca A-446 is a fully automatic high-speed pre & post vacuum steam sterilizer.
This model is an electrically heated sterilizer, which operates with saturated steam as a sterilizing agent, and has a temperature between 121°C (250°F) and 134ºC (273°F) and pressure up to 2.5 bars (36.3 psi).
The autoclave is classified as Class IIb according to MDD 93/42/EEC. The autoclave is designed as a Large Steam Sterilizer in accordance with EN285 and as Class I in accordance with EN60601-1, continuously operated, ordinary equipment without applied parts and without signal input-output parts. The device is not intended for use in the presence of flammable mixtures.

The sterilizer includes the following features:

  • Large capacity sterilization chamber
  • Vacuum pump for evacuation of the chamber
  • Fully automatic door locking system – activated with one button on the display or with foot pedal
  • Water reservoir for process and used water retention
  • Water pump for water circulation
  • Condenser and collector for condensation and collection of water
  • Temperature sensors and a pressure transducer to monitor both vacuum and pressurized states
  • Control valves operating at programmed intervals

Application
The unit is designed to cover a large field of applications for hospital CSSDs, pharmaceutical and biotechnological applications.

Dimensions
Inner chamber dimensions W x H x D: 406 x 406 x 670 mm

Chamber volume: 110 Litres

External dimensions W x H x D: 660 x 1900 x 910 mm  

Max. electric power with steam generator 14 kW, 3 phase, 380-400V – 3 x 25A, 50/60 Hz

 Technical data

Inner chamber dimensions W x H x D *

406 x 406 x 670 mm

Chamber volume *

110 l

External dimensions W x H x D

660 x 1900 x 910 mm

Approximate weight

350 kg

Power supply**

3 ph. 380-400 V, 50/60 Hz

Available sterilization cycles

Flash 134 °C / Unwrapped 134 °C / Wrapped 134 °C / Prion 134 °C / Porous 121 °C