DS – 09 Syringe Pump VISMA-PLANAR

Product Code:DS – 09

checked-shape
In Stock
40 160 грн
  • The consultation on assortment of equipment
  • The manufacturer's official warranty is 12 months
  • Free delivery
  • Free commissioning and staff training
  • Certified customer service
  • Service support during the warranty and post-warranty period


DS – 09 Syringe Pump VISMA-PLANAR

Means to infuse high-performance medicines at setup performance rate    

  • Compatible with syringes by various vendors
  • Automatic syringe detection, syringe size indication
  • Lists of medicines and syringe brands
  • Infusion setting by one (capacity) or two (capacity-time, volume-time, capacity-volume) parameters
  • Dosing (μg/kg/min, mg/kg/min, μg/kg/hour, mg/kg/hour, μg/hour, mg/h), bodyweight setup (kg), solution concentration setup (μg/ml, mg/ml) with automatic injection rate calculation
  • Programmable menu
  • BOLUS mode (programmable / manual)
  • Standby mode
  • Saving setup parameters after shutdown
  • Adjustment with infusion uninterrupted
  • Mains or internal battery power supply
  • Automatic switchover to internal power source in case of mains failure
  • Battery charge indicator
  • 1 to 19 min prior expiration alarm
  • Visual and audio alarm for main patient safety parameters
  • Event recording in nonvolatile memory
  • IP22 moist-proof casing
  • 12V external power socket
  • Universal bracket for infusion-rack or rail installation




Specification:

Rate:
0.1 – 999.9 ml/h
BOLUS rate:
1 – 1200 ml/h
BOLUS capacity:
0.0 – 59.9 ml
Infusion capacity setup up:
to 999.9 ml
Infusion time setup up:
to 99 h 59 min
KVO:
0.0 – 5.9 ml/h
Accuracy:
±1%
Occlusion levels:
60, 100, 140 kPa
Applicable syringes:
10, 20, 50/60 ml
Event log over:
150 records
Battery life over:
5 h
Power supply:
mains 230 V, 50 Hz, battery NiMH 12 V
Power consumption:
20 VA
Overall dimensions:
335 × 150 × 115 mm
Weight (w/o power cord):
2.2 kg


DS – 09 Syringe Pump VISMA-PLANAR

Means to infuse high-performance medicines at setup performance rate    

  • Compatible with syringes by various vendors
  • Automatic syringe detection, syringe size indication
  • Lists of medicines and syringe brands
  • Infusion setting by one (capacity) or two (capacity-time, volume-time, capacity-volume) parameters
  • Dosing (μg/kg/min, mg/kg/min, μg/kg/hour, mg/kg/hour, μg/hour, mg/h), bodyweight setup (kg), solution concentration setup (μg/ml, mg/ml) with automatic injection rate calculation
  • Programmable menu
  • BOLUS mode (programmable / manual)
  • Standby mode
  • Saving setup parameters after shutdown
  • Adjustment with infusion uninterrupted
  • Mains or internal battery power supply
  • Automatic switchover to internal power source in case of mains failure
  • Battery charge indicator
  • 1 to 19 min prior expiration alarm
  • Visual and audio alarm for main patient safety parameters
  • Event recording in nonvolatile memory
  • IP22 moist-proof casing
  • 12V external power socket
  • Universal bracket for infusion-rack or rail installation




Specification:

Rate:
0.1 – 999.9 ml/h
BOLUS rate:
1 – 1200 ml/h
BOLUS capacity:
0.0 – 59.9 ml
Infusion capacity setup up:
to 999.9 ml
Infusion time setup up:
to 99 h 59 min
KVO:
0.0 – 5.9 ml/h
Accuracy:
±1%
Occlusion levels:
60, 100, 140 kPa
Applicable syringes:
10, 20, 50/60 ml
Event log over:
150 records
Battery life over:
5 h
Power supply:
mains 230 V, 50 Hz, battery NiMH 12 V
Power consumption:
20 VA
Overall dimensions:
335 × 150 × 115 mm
Weight (w/o power cord):
2.2 kg


Related Products