Product Code:INDIascan
Complex x-ray diagnostic digital INDIascan (for chest radiography)
INDIascan CRD is designed for full-screen chest radiography - to detect early tuberculosis, cancer and other diseases (specific pneumonia type COVID-19) with image acquisition on a monitor, digital processing and PC recording in digital form. It is possible to control the apparatus from the interactive control panel (automated workplace of the x-ray laboratory assistant). Voice support for the examination procedure is available.
The main advantages of the Complex are:
Composition of the Complex:
Unlike other X-ray machines, INDIascan is equipped with a high-frequency power supply unit with a monoblock structure, which has the undoubted advantages of:
Technical Data
| Power consumption | of 16 kW |
The anode voltage is regulated in the range | from 40 to 120 kV with a step change of 1 kV |
| The anode current is regulated in the range | from 40 to 120 mA with a step change of 1 mA |
| The size of the survey field - | not less than 430x430mm |
| Average exposure time | from 0.01 to 2.5 s single-phase |
Spatial resolution | of at least 4.0 pairs of lines / mm. |
| Type of X-ray emitter | with rotating anode |
Power supply | 220 ± 22 V, 50 ± 1 Hz |
Complex x-ray diagnostic digital INDIascan (for chest radiography)
INDIascan CRD is designed for full-screen chest radiography - to detect early tuberculosis, cancer and other diseases (specific pneumonia type COVID-19) with image acquisition on a monitor, digital processing and PC recording in digital form. It is possible to control the apparatus from the interactive control panel (automated workplace of the x-ray laboratory assistant). Voice support for the examination procedure is available.
The main advantages of the Complex are:
Composition of the Complex:
Unlike other X-ray machines, INDIascan is equipped with a high-frequency power supply unit with a monoblock structure, which has the undoubted advantages of:
Technical Data
| Power consumption | of 16 kW |
The anode voltage is regulated in the range | from 40 to 120 kV with a step change of 1 kV |
| The anode current is regulated in the range | from 40 to 120 mA with a step change of 1 mA |
| The size of the survey field - | not less than 430x430mm |
| Average exposure time | from 0.01 to 2.5 s single-phase |
Spatial resolution | of at least 4.0 pairs of lines / mm. |
| Type of X-ray emitter | with rotating anode |
Power supply | 220 ± 22 V, 50 ± 1 Hz |